Product Model | theoretical displacement mL/r | Maximum pressure | Allowable speed | Drive Power | Quality | |||||||
For high pressure Specific oil | Anti-wear Hydraulic oil | Ordinary Hydraulic oil | antiwear water Glycol liquid | Water B 2 alcohol liquid | water in oil Emulsion | phosphate ester liquid | Minimum | Highest | ||||
PV2R1-4 | 4.3 | 21 | 17.5 | 16 | 16 | 7 | 7 | 16 | 750 | 1800 (1200) | 2.1 | 8 |
PV2R1-6 | 6.1 | 3.2 | ||||||||||
PV2R1-8 | 8.5 | 4.5 | ||||||||||
PV2R1-10 | 10.4 | 5.4 | ||||||||||
PV2R1-12 | 13 | 6.1 | ||||||||||
PV2R1-14 | 14.2 | 6.9 | ||||||||||
PV2R1-17 | 16.8 | 7.9 | ||||||||||
PV2R1-19 | 19.4 | 9.6 | ||||||||||
PV2R1-23 | 23.3 | 10.5 | ||||||||||
PV2R1-25 | 24.4 | 12.5 | ||||||||||
PV2R1-28 | 28.4 | 14.0 | ||||||||||
PV2R1-31 | 29.5 | 16 | 16 | 15.5 | ||||||||
Model Description

Installation and use
Note: 1. Nominal displacement “4”、“6”、“8” pump, when the pressure exceeds 16MPa, the speed should exceed 1450r/min.
2. When using large displacement single pump and corresponding double pump at high speed, the negative pressure of suction port should be reduced.
3. The value in () is the value of using phosphate liquid and aqueous hydraulic liquid.
4. For special requirements of low noise occasions, it is recommended that the working speed of 1000r/min.
5. When the working fluid is phosphate liquid, due to the need to use special sealing (fluorine rubber), please add [F-] before ordering the specified model.
6. The driving power is under the working conditions of P = 16MPa and n = 1500r/min.Installation and connection dimensions