Product characteristics
This pump is driven by the same shaft two, PV2R type single pump in parallel assembled in the same shell, the output flow can be supplied to independent circuit.
Specification drawing

Application field of motor pump group

Oil pump selection
1. Determine the type of quantitative pump
Vane pump: small pressure pulsation, high volumetric efficiency, flow does not follow the pressure change
Gear pump: large pressure pulsation, slightly lower volumetric efficiency, slightly lower requirements for oil cleanliness, and non-adjustable flow
2. Determine pressure, flow, noise and temperature rise
Determine the pressure and flow parameters of the oil pump according to the power and speed of the system, taking into account the demand for sound and temperature rise.
3. Proofreading installation dimensions
Determine the connection mode of the oil pump and the motor, and calibrate the installation size of the oil pump
4. Determine the color appearance
There are black, green, silver, phosphating and other colors for choice, indicating the color requirements
5. Special requirements
Indicate the special requirements for the oil pump and its accessories, such as all copper, etc.
6. Parameter code
Parameter code = Parameter code/Mounting method/Color/Special requirements
Example: 91010504/Spline/Black/All Copper
Notes on the use of oil pump
※ installation
The concentricity of the pump and motor installation shaft is controlled within 0.1mm, and the angle error is less than 0.2 degrees:
※ Piping
Oil suction piping: for the self-priming vane pump, the distance between the oil suction port and the liquid surface is less than 1 m;
※ exhaust
When it is first put into use, the motor should be started repeatedly under no pressure to remove air from the pump and suction.
Precautions for the use of hydraulic oil
1. Selection of hydraulic oil
Use hydraulic oil with viscosity of 30-50cst(1SOVG-32) at 40 ℃ for recommend below 70bar
More than 70bar recommend use 40 ℃ viscosity 50-70cst(1SOVG-68) hydraulic oil
2. Oil temperature range
In order to ensure long-term reliable operation of the system, the working oil temperature is controlled at 15-60 ℃
3. Oil cleanliness
Always install a suitable filter unit in the equipment system, and regularly replace the cleaning filter element.
4. Oil replacement cycle
Regular oil change method: the time for the first time to replace the hydraulic oil of the equipment is half a year, and then once a year. Visual oil change method: when the oil turns black or Milky White, the oil should be replaced in time. Sampling and testing method: regular sampling and testing of oil to determine whether its performance indicators meet the standards, not up to standard immediately replaced, suitable for key equipment and large equipment
Performance parameter test environment
1. Hydraulic oil ISOVG-32, motor 4P;
2. Temperature rise standard: room temperature 30 ℃,60L oil tank, oil temperature rise during continuous operation